400-860-6886
YXL priority valve is a fixed differential pressure reducing hydraulic component, no matter how the load sensing steering system load pressure and oil pump oil supply changes, the priority valve can keep the flow of the supply steering gear is always equal to the product of the steering wheel speed and the steering gear displacement to ensure the required flow of the steering gear. It is used with BHR5, BPB5, BPBS5T and other load sensing full hydraulic steering gear. Widely used in agricultural machinery, construction machinery, forklift and other fields. It is divided into dynamic signal and static signal in two forms
Displacement Range: 50-200ml/r
Nominal Rated Flow:60L/min
Steering Torque 0.9-2.4N.m
For Example:
DYXL priority valve, dynamic signal, maximum inlet flow 160L/min. The safety valve pressure is 12Mpa, the control pressure is 7Bar (0.7Mpa), the internal control form, the oil thread P and EF are G3/4-14, CF is G1/214, LS and T are G1/4-19.
Priority valve product number :DYXL-F160L-12N7-D